| TCII BLENDING CONTROLS |
| • |
6 virgin aggregate VFD bins |
| • |
Aggregate virgin scale |
| • |
1 recycle bin over 1 recycle belt scale |
| • |
1 mineral filler (volumetric or gravimetric) |
| • |
1 additive pump |
| • |
1 asphalt VFD pump (temperature compensated) |
| • |
Calibration for all scales, pumps and feeders: |
|
| |
Operator selectable automatic feeder calibration |
| |
Multiple material calibration for bins |
|
| • |
Unlimited mix design stored on hard disk drive |
| • |
Material mix design tolerances |
| • |
Material mix start/stop timing |
| • |
Communication with Astec "WM2000" |
|
| |
Operator selectable automatic feeder calibration |
|
| Burner Controls |
| • |
Commands and monitoring of flame safeguard device |
| • |
Controls burner position via "Burner Profiles" with individual settings for: |
|
| |
Combustion air (VFD) |
| |
2 fuels |
|
Controls to operator selectable |
|
Final mix temperature |
|
Aggregate temperature |
|
Baghouse inlet temperature |
|
Temperature trending |
|
| Alarming |
| • |
Text message and logging of all system errors |
| • |
Audible alerts for key system errors |
| Baghouse Controls |
| • |
Controls pressure drop by automatically adjusting pulse cycle depending on monitored pressure drop |